MARC details
| 000 -LEADER |
| fixed length control field |
04001nam a22003377a 4500 |
| 003 - CONTROL NUMBER IDENTIFIER |
| control field |
OSt |
| 005 - DATE AND TIME OF LATEST TRANSACTION |
| control field |
20250930165726.0 |
| 008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION |
| fixed length control field |
250930b |||||||| |||| 00| 0 eng d |
| 020 ## - INTERNATIONAL STANDARD BOOK NUMBER |
| International Standard Book Number |
9780357766972 |
| 040 ## - CATALOGING SOURCE |
| Language of cataloging |
eng |
| Transcribing agency |
TUPM |
| Description conventions |
rda |
| 050 ## - LIBRARY OF CONGRESS CALL NUMBER |
| Classification number |
TK 3286 |
| Item number |
S55 2024 |
| 100 ## - MAIN ENTRY--PERSONAL NAME |
| Personal name |
Simmons, J. Philip |
| 245 ## - TITLE STATEMENT |
| Title |
Electrical wiring residential : |
| Remainder of title |
based on the 2023 National Electrical Code/ |
| Statement of responsibility, etc. |
J. Philip Simmons, Derek Vigstol and Ray C. Mullin |
| 250 ## - EDITION STATEMENT |
| Edition statement |
21st edition |
| 264 ## - PRODUCTION, PUBLICATION, DISTRIBUTION, MANUFACTURE, AND COPYRIGHT NOTICE |
| Place of production, publication, distribution, manufacture |
Boston, Massachusetts, |
| Name of producer, publisher, distributor, manufacturer |
Cengage, |
| Date of production, publication, distribution, manufacture, or copyright notice |
c2024. |
| 300 ## - PHYSICAL DESCRIPTION |
| Extent |
xxiii, 840 pages : |
| Other physical details |
color illustrations ; |
| Dimensions |
28 cm + [6] folded plans (in pocket) |
| 336 ## - CONTENT TYPE |
| Source |
rdacontent |
| 337 ## - MEDIA TYPE |
| Source |
rdamedia |
| 338 ## - CARRIER TYPE |
| Source |
rdacarrier |
| 504 ## - BIBLIOGRAPHY, ETC. NOTE |
| Bibliography, etc. note |
Includes bibliographic references and index. |
| 505 ## - FORMATTED CONTENTS NOTE |
| Formatted contents note |
General information for electrical installations<br/>Specifications, electrical symbols, and outlets<br/>Determining the required number of branch circuits, lighting outlets, and receptacle outlets<br/>Conductor sizes and types, wiring methods, wire connections, voltage drop, and neutral conductor sizing<br/>Conductor identification, switch control of lighting circuits, bonding/grounding of wiring devices, and induction heating<br/>Ground-fault circuit interrupters, arc-fault circuit interrupters, surge protective devices, immersion detection circuit interrupters, and appliance leakage current interrupters<br/>Luminaires, ballasts, and lamps<br/>Lighting branch circuit for the front bedroom<br/>Lighting branch circuit for the master bedroom<br/>Lighting branch circuit<br/>bathrooms, hallway<br/>Lighting branch circuit<br/>front entry, porch, post light, underground wiring<br/>Lighting branch circuit and small-appliance branch circuits for the kitchen<br/>Lighting branch circuit for the living room<br/>Lighting branch circuit for the study/bedroom<br/>Dryer outlet, lighting, and receptacle circuits for the laundry, powder room, rear entry hall, and attic<br/>Branch circuits for the garage and outdoors<br/>Recreation room<br/>Lighting branch circuit, receptacle circuits for workshop<br/>Special-purpose outlets<br/>water pump, water heater<br/>Special-purpose outlets for ranges, counter-mounted cooking unit, and wall-mounted oven<br/>Special-purpose outlets<br/>food waste disposer, dishwasher<br/>Special-purpose outlets for the bathroom ceiling heat/vent/lights, the attic fan, and the hydromassage tub<br/>Special-purpose outlets<br/>electric heating, air conditioning<br/>Gas and oil central heating systems<br/>Television, telephone, and low-voltage signal systems<br/>Smoke, heat, carbon monoxide alarms, and security systems<br/>Feeder and service-entrance calculations<br/>Installing feeders and service-entrance equipment<br/>grounding and bonding<br/>Overcurrent protection<br/>fuses and circuit breakers<br/>Swimming pools, spas, hot tubs, hydromassage baths, and electrically powered pool lifts<br/>Wiring for the future: home automation systems<br/>Standby power systems<br/>Residential photovoltaic systems |
| 520 ## - SUMMARY, ETC. |
| Summary, etc. |
"What's new: The text covers new and updated wiring requirements, including those for peninsular and island counterspaces in kitchens, which have changed significantly, and wiring for receptacle outlets in an attached or detached garage with electric power, which may now supply outside outlets in a limited way (per NEC 210.52(G)(1)). The text teaches students both recognized methods of calculating electrical load on feeders and services and the new or revised 2023 NEC® rules relevant to service installation and surge protection." |
| Expansion of summary note |
Publisher |
| 590 ## - CITATION |
| Citation |
Simmons, J. P., Vigstol, D., & Mullin, R. C. (2024). Electrical wiring residential: Based on the 2023 National Electrical Code (21st ed.). Boston, MA: Cengage. |
| 650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
| Topical term or geographic name entry element |
Dwellings |
| Form subdivision |
Standards |
| General subdivision |
Electric equipment |
| Geographic subdivision |
United States. |
| 650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
| Topical term or geographic name entry element |
Electric wiring, Interior |
| General subdivision |
Standards |
| Geographic subdivision |
United States. |
| 650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
| Topical term or geographic name entry element |
National Electrical Code. |
| 700 ## - ADDED ENTRY--PERSONAL NAME |
| Personal name |
Derek Vigstol |
| Relator term |
author |
| 700 ## - ADDED ENTRY--PERSONAL NAME |
| Personal name |
Ray C. Mullin |
| Relator term |
author |
| 942 ## - ADDED ENTRY ELEMENTS (KOHA) |
| Source of classification or shelving scheme |
Library of Congress Classification |
| Koha item type |
Book |
| Suppress in OPAC |
No |