MARC details
| 000 -LEADER |
| fixed length control field |
02220nam a22002537a 4500 |
| 003 - CONTROL NUMBER IDENTIFIER |
| control field |
OSt |
| 005 - DATE AND TIME OF LATEST TRANSACTION |
| control field |
20250220100833.0 |
| 008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION |
| fixed length control field |
250220b |||||||| |||| 00| 0 eng d |
| 040 ## - CATALOGING SOURCE |
| Original cataloging agency |
TUPM |
| Language of cataloging |
English |
| Transcribing agency |
TUPM |
| Modifying agency |
TUPM |
| Description conventions |
rda |
| 050 ## - LIBRARY OF CONGRESS CALL NUMBER |
| Classification number |
BTH TK 146 |
| Item number |
Q58 2023 |
| 100 ## - MAIN ENTRY--PERSONAL NAME |
| Personal name |
Quito, Luisito L. |
| Relator term |
author |
| 245 ## - TITLE STATEMENT |
| Title |
Development of a safety protection device for inline extraction fan/ |
| Statement of responsibility, etc. |
Luisito L. Quito .-- |
| 260 ## - PUBLICATION, DISTRIBUTION, ETC. |
| Place of publication, distribution, etc. |
Manila: |
| Name of publisher, distributor, etc. |
Technological University of the Philippines, |
| Date of publication, distribution, etc. |
2023. |
| 300 ## - PHYSICAL DESCRIPTION |
| Extent |
xi, 114pages: |
| Dimensions |
29cm. |
| Accompanying material |
+1 CD-ROM (4 3/4in.) |
| 336 ## - CONTENT TYPE |
| Source |
rdacontent |
| 337 ## - MEDIA TYPE |
| Source |
rdamedia |
| 338 ## - CARRIER TYPE |
| Source |
rdacarrier |
| 500 ## - GENERAL NOTE |
| General note |
Bachelor's thesis |
| 502 ## - DISSERTATION NOTE |
| Dissertation note |
College of Industrial Technology .-- |
| Degree type |
Bachelor of Technology major in Electrical Engineering Technology: |
| Name of granting institution |
Technological University of the Philippines, |
| Year degree granted |
2023. |
| 504 ## - BIBLIOGRAPHY, ETC. NOTE |
| Bibliography, etc. note |
Includes bibliography |
| 520 ## - SUMMARY, ETC. |
| Summary, etc. |
Boilers are vital for providing heat and hot water in the hotel industry. However, the<br/>extraction fan component of the boiler system has a flaw that its fan motor runs<br/>continuously, leading to overheating and frequent replacements. This issue affects the<br/>maintenance team, causing them to inhale harmful gases produced by the overloaded<br/>motor. To address this problem, a prototype was developed which includes a safety device<br/>for the extraction fan controller, an electrical interlocking relay, an overload protection<br/>relay, an emergency shutdown button, a selector switch with auto/off/manual modes, a<br/>counter timer for monitoring motor usage, a carbon monoxide sensor with an alarm, an<br/>LCD screen for monitoring, and a loud buzzer. The prototype has been tested and<br/>automatically disengages the extraction fan when the water temperature exceeds the<br/>allowed limit. Likewise, its overload relay was also tested and adjusted to prevent motor<br/>overheating. The prototype received an excellent mean score of 4.74 from respondents<br/>composed of Asst. Director of Engineering, Duty Engineer, Engineering Supervisor, and<br/>Technicians on duty. These results indicate that the extraction fan motor now fulfills its<br/>purpose and has the potential to prevent overheating. |
| 650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
| Topical term or geographic name entry element |
Electrical engineering |
| 942 ## - ADDED ENTRY ELEMENTS (KOHA) |
| Source of classification or shelving scheme |
Library of Congress Classification |
| Koha item type |
Bachelor's Thesis CIT |
| Suppress in OPAC |
No |