Effectiveness of banana sheath in thermal insulation board using isocyanate resin as binder/ Godofredo A. Corto, Jeric Rhoy F. Gamarcha, Vince Aaron S. Libari, Emmanuel Jericho O. Marcos, John David O. Pabillore, and Justine J. Silaya .--
Material type:
TextPublication details: Manila: Technological University of the Philippines, 2023.Description: x,114pages: 29cmContent type: - BTH TH 438 C67 2023
| Item type | Current library | Shelving location | Call number | Copy number | Status | Date due | Barcode |
|---|---|---|---|---|---|---|---|
Bachelor's Thesis CIT
|
TUP Manila Library | Thesis Section-2nd floor | BTH TH 438 C67 2023 (Browse shelf(Opens below)) | c.1. | Not for loan | BTH0004535 |
Browsing TUP Manila Library shelves, Shelving location: Thesis Section-2nd floor Close shelf browser (Hides shelf browser)
Bachelor's thesis
College of Industrial Technology .-- Bachelor of Engineering Technology major in Construction Technology: Technological University of the Philippines, 2023.
Includes bibliography:
Increases in the production of building materials also contribute to an increase in
greenhouse gas emissions and the depletion of natural resources. The development of
useful composite materials out of agricultural waste has emerged as a desirable option in
recycling. Insulation is one of these materials, which is becoming increasingly important
in the energy performance of buildings and, in turn, reducing the detrimental
environmental effects of the built environment. In this paper, the agricultural waste of
banana sheath was independently utilized in the production of insulation board, Isocyanate was used as a binder and was manufactured using 97:3 95:5 93:7, wherein the
first variable is the proportion of the banana sheath, and the second is the proportion of
Isocyanate in ratio with a board and a target density of 0.5 kg/cm3. The Insulation board
was subjected to Thickness Swelling (TS) and Water Absorption Test (WA) to determine
the Physical Properties, Internal Bond Test, and Face Screw Holding Test (FSHT) for the
Mechanical Properties and Temperature Resistance to determine the resistance to heat
flow in Thermal Properties. All of the tests conducted are inclined to the Philippines
National Standard (PNS) requirements for general-purpose medium-density fiberboard. Results revealed that Insulation Board did not pass any of the standard requirements of
PNS ISO 16895-2:2015 on both mechanical and physical property tests. For the thermal
property, all of the mix ratios meet the standard of ASTM C518 Under the test method
specifications that thermal resistance must be greater than 0.10 m2 K/W.