Local cover image
Local cover image
Image from OpenLibrary
Custom cover image
Custom cover image

Property characterization of cement-bounded particle board using powdered scoria as partial replacement to cement and waste falcata particles as raw materials/ Evangeline M. Aguando, Alyssa Marie P. Camilon, Monette V. Nedic, and John Patrick B. Vicencio.--

By: Contributor(s): Material type: TextTextPublication details: Manila: Technological University of the Philippines, 2019.Description: xvi, 80pages: 29cmContent type:
Media type:
Carrier type:
Subject(s): LOC classification:
  • BTH TA 145  A38 2019
Dissertation note: College of Engineering.-- Bachelor of science in civil engineering; Technological University of the Philippines, 2019. Summary: Increase in need of housing unit in the Philippines meant increase in cement manufacture. As the population tremendously grow, the possibility that the source of cement may one day be depleted is at hand. Researchers now focus on finding ways to reduce manufacture of cement by producing sustainable construction materials utilizing alternatives for replacement of cement. The purpose of this study is to investigate the property characterization of cement bonded particle board (CPB) using scoria as partial replacement to cement. Laboratory size CPBs with dimensions of 1.25 x 30 x 30 cm were produced using cement: falcata particles ratio of 60/40 and scoria content as cement replacement of 0%SC, 5%SC, 10%SC, 15%SC, 20%SC, 25%SC, 30%SC and 35%SC. The falcata particles collected were hamermilled and soaked in water for 24 hours then air-dried in equilibrium moisture content. Cement and water were mixed with the particles until thoroughly coated with cement. The mixtures were mat formed, pressed and clamped for 24 hours. After the boards were cured and conditioned for 28 days, the boards were tested for their mechanical and physical properties and compared with control specimen (0%SC). The physical properties of boards gave remarkable result for all set with scoria replacements such that the least TS is at 0.15% while 12.33% in WA. For the mechanical properties, MOR of scoria replacements of 20%SC and 25%SC produced boards exceeding PNS/CTP 07 (1990) standard for non-structural 12 mm thick boards of 6.75 MPa. Also, the recorded maximum load resistance in NPT is at 121.55 kgf (1.19 kN) at 35%SC replacement. The results showed that the properties of the boards were influenced by the amount of scoria put in replacement to cement. Also 20%SC replacement produced good quality boards by satisfying the minimum requirements of PNS/CTP 07:1990 and exceeding performance requirements from commercial plants.
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Item type Current library Shelving location Call number Copy number Status Date due Barcode
Bachelor's Thesis COE Bachelor's Thesis COE TUP Manila Library Thesis Section-2nd floor BTH TA 145 A38 2019 (Browse shelf(Opens below)) c.1. Not for loan BTH0003471

Bachelor's Thesis

College of Engineering.-- Bachelor of science in civil engineering; Technological University of the Philippines, 2019.

Includes bibliographic references and index.

Increase in need of housing unit in the Philippines meant increase in cement
manufacture. As the population tremendously grow, the possibility that the source of
cement may one day be depleted is at hand. Researchers now focus on finding ways to
reduce manufacture of cement by producing sustainable construction materials utilizing
alternatives for replacement of cement. The purpose of this study is to investigate the
property characterization of cement bonded particle board (CPB) using scoria as partial
replacement to cement. Laboratory size CPBs with dimensions of 1.25 x 30 x 30 cm were
produced using cement: falcata particles ratio of 60/40 and scoria content as cement
replacement of 0%SC, 5%SC, 10%SC, 15%SC, 20%SC, 25%SC, 30%SC and 35%SC.
The falcata particles collected were hamermilled and soaked in water for 24 hours then
air-dried in equilibrium moisture content. Cement and water were mixed with the
particles until thoroughly coated with cement. The mixtures were mat formed, pressed
and clamped for 24 hours. After the boards were cured and conditioned for 28 days, the
boards were tested for their mechanical and physical properties and compared with
control specimen (0%SC). The physical properties of boards gave remarkable result for
all set with scoria replacements such that the least TS is at 0.15% while 12.33% in WA.
For the mechanical properties, MOR of scoria replacements of 20%SC and 25%SC
produced boards exceeding PNS/CTP 07 (1990) standard for non-structural 12 mm thick
boards of 6.75 MPa. Also, the recorded maximum load resistance in NPT is at 121.55 kgf
(1.19 kN) at 35%SC replacement. The results showed that the properties of the boards
were influenced by the amount of scoria put in replacement to cement. Also 20%SC
replacement produced good quality boards by satisfying the minimum requirements of
PNS/CTP 07:1990 and exceeding performance requirements from commercial plants.

There are no comments on this title.

to post a comment.

Click on an image to view it in the image viewer

Local cover image



© 2025 Technological University of the Philippines.
All Rights Reserved.

Powered by Koha